About This Facility
Services and Equipment
Publications
Awards & Associations
Metadata
Other Facilities at this Institution:
University of California Davis, 1 Shields Avenue
3425 Tupper Hall, Dept. of Medical Microbiology & Immunology
Davis, CA 95616
United Stateshttp://www.ucdmc.ucdavis.edu/cancer/research/sharedresources/flowcytometry.htmlcite this facility
Bridget McLaughlin
Last Updated: 01/07/2025
The UC Davis Flow Cytometry Shared Resource operates cell sorting and analytic cytometry equipment, including nanoscale and spectral flow cytometry support. We have two full-service locations, one on the main academic campus in Davis, CA and another in a separate facility at the UC Davis Medical Center in Sacramento, CA. We offer multiparameter cell sorting and analytic cytometry services, instrumentation training and comprehensive flow cytometry training for UCD, UC, and industry scientists. Comprehensive, week long flow cytometry training is offered online in winter and summer, with live-streamed lecture and laboratory instruction - this course is open to all interested participants and typically costs less than $1,000.00 for a full week of training. Single cell sorting and with phenotypic indexing is offered, Please contact us for more information on these services.
Services are offerred outside of University of California, Davis
Consulting is offerred outside of University of California, Davis
50 Nm Exosome And Microparticle Analysis
Online Flow Cytometry Training: Semi-Annual Comprehensive Week-Long Cytometry Course
BD LSRFortessa Fortessa Flow Cytometer
BD LSRFortessa cell analyzer offers the ultimate in choice for flow cytometry, providing power, performance, and consistency. Designed to be and expandable, the BD LSRFortessa has the flexibility to support the expanding needs of multicolor flow cytometry assays. The BD LSRFortessa system can be configured with up to 7 lasers*,blue, red, violet, UV and yellow-green. The instrument can accommodate the detection of up to 18 colors simultaneously with a defined set of optical filters that meet or exceed the majority of today's assay requirements. BD FACSDiva software controls the efficient setup, acquisition, and analysis of flow cytometry data from the BD LSRFortessa workstation. The software is common across BD FACS instrument families, including the BD FACSCanto cell analyzer and BD FACSAria cell sorter systems. [Product Link]
cite this instrument
Beckman Coulter CytoFLEX Flow Cytometer
Flow Cytometer provides performance needed for sensitivity and resolution throughout all configurations. [Product Link]
cite this instrument
Beckman Dickinson Aria IIu Flow Cytometer
Aria has four lasers, 405, 488, 561 and 633 nm, and can detect light in sixteen photomultiplier tubes. Its primary function is to examine complex populations of cells and yield pure populations of cells. The Aria can sort lymphocytes at a rate of approximately 15,000 events per second. For larger cells, the rate is much slower in order to optimize the passage of cells through the instrument. Cells from single populations can be sorted into 96-well plates. Alternatively, the Aria can sort into two 15-ml tubes or four 5-ml tubes. The Aria can purify samples that are simply positive and negative for a single fluorophore or as complex as nine-color samples with intricate gating schemes. The BD FACSAria IIu cell sorter is a high speed benchtop digital flow cytometer equipped with a sensitive, fixed-alignment cuvette flow cell. It has three spatially separated lasers - 405 nm, 488 nm and 633 nm. Its primary function is to analyze complex populations of cells and yield pure populations of cells meeting defined criteria. The sorter can purify samples that are simply positive and negative for a single fluorophore or as complex as multi-color samples with complex gating strategies. Sorting can be performed into two or four tubes with speeds up to 25,000 events/second. The system sorts by incorporating cells from the sample tube into a stream of sterile PBS. The stream is interrogated by the lasers at the flow cell and the system electronics keeps track of each cell as they pass through the laser and determines specific cells that meet the sort criteria. A transducer vibrates the stream and induces droplet formation, with cells in the stream being incorporated into the droplets. If a cell meets the sorting criteria and is in the last drop before the break off, the instrument will charge that drop. The charged droplet is then deflected into the proper collection tube by the charge plates. Different cell types can be sorted with the use of 70 ?m, 85 ?m and 100 ?m nozzles. If you need a yellow-green (561 nm) laser, check the BD FACSAria III instead. [Product Link]
cite this instrument
Beckman Coulter Cytoflex NANO
Specialized flow cytometer capable of detecting 40 nm polystyrene particles
MoFlo 10 color cell sorter
inFlux 16 color cell sorter with index sorting
*Large cell sorting with 200um nozzle on inFlux sorter
*Enhanced small particle detection on inFlux sorter
Fluidigm BioMark qPCR and genotyping
Compucyte laser scanning microscope-based cytometer for tissue and adherent cytometry
18 color, 5 laser (355, 405, 488, 561 & 638nm) Fortessa analytic cytometer
16 color, 3 laser (405, 488, 638nm) LSRII analytic cytometer
12 color, 3 laser (405, 488, 635) Stratedigm analytic cytometer - optimal for small particle analysis
CantoI 2 laser cytometer
FACScan 2 laser cytometer
No publications have been associated with this facility
Links
All the links listed resolve to this core profile
https://coremarketplace.org/?FacilityID=612Institution
Institution ROR ID: https://ror.org/05rrcem69Keywords:
Flow, cytometry, laser, scanning, cell, sorting, data, analysis, training, service, core, ABRF, USEDit
Resource Type:
access service resource, core facility, service resource
Citation:
University of California Davis Flow Cytometry Shared Resource Laboratory Core Facility (RRID:SCR_017826)
Your Email:
Your Phone (optional):
Message: